Home / products / flow control systems / Distribution valve
Mux Distribution

Microfluidic Distribution valve

12/1 rotary bidirectional microfluidic valve
Sequential microfluidic liquid injection

Quickly swap your biological media or chemical solutions

Workflow microfluidic automation

Save time thanks to sequence programming

Rotary selector valve

Switch between up to 12 liquids

Perfuse solutions into a microfluidic chip

Inject 1 sample into 12 outputs or 12 samples into 1 output

Talk to an expert

Features & benefits

Perform microfluidic sequential injection with the 12/1 Rotary Selector Bidirectional Valve.

Combined with the OB1 MK4 pressure controller, the MUX Distribution valve will allow you to automate injection in microfluidic experiments, program perfusion experiments, sequentially supply different reagents and many more applications.

12/1 distribution Valve

MUX Distribution valve with a Manifold 13 ports to 12 reservoirs

Benefits

Several solutions from one outlet or one feed directed into different outlets.

Use the MUX Distribution valve to sequentially inject up 12 different solutions into one microfluidic line for sample collections or parallel experiments.

  • Low internal volume
  • Fast switching time 
  • Workflow microfluidic automation
  • Smooth switches:  no disruption of the flow
  • Easy setup and operation (plug and play software + standard fluidic connection)

Bidirectional 13 ports/ 12 positions sequential injection from 12 different samples into 1 output/input

 

Mux Distribution Valve, fluid switching in a microfluidic chip

   Key advantages

    • Valve flexibility: 13 ports
    • Easy setup: standard ¼-28 fluidic fittings
    • Possibility to chose the sense of rotation
    • High chemical compatibility
    • Lowest internal volume: 3.5 µL 
      • No dead volume
    • Switching time (average): 156 ms
    • Wetted materials: PCTFE, PTFE

 

 

Do you know how to perform multiple liquid switching in microfluidics?

For more information on how to perform a stable and precise flow switch, please check out our dedicated sequential fluid injection pack!

The MUX Distrib’ 12/1 can be used in various fields of application and for any experiment that requires successive injection of fluids: from organic synthesis, flow chemistry, drug screening, biochemical and electrochemical sensor calibration, calibration (bench testing), sensors test rig, toxicity test, Seq-Fish experiment…

Publications

Adaptable pulsatile flow generated from stem cell-derived cardiomyocytes using quantitative imaging-based signal transduction

T. Qian et al., Lab on a  Chip, 2020, 20, 3744-3756, DOI: 10.1039/D0LC00546K

Microfluidic platform for 3D cell culture with live imaging and clone retrieval

C. Mulas et al., Lab on a chip, 2020, 20, 2580-2591, DOI: 10.1039/D0LC00165A

Microfluidic Control of Nucleation and Growth of CaCO3

D. K. Dysthe et al. Cryst. Growth Des. 2018, 18, 8, 4528–4535

  • For all the publications using our products, please click here.
  • For all the application notes and reviews based on our product, please click here.

Performances Port to port switching time (ms) 156 ms
Maximum valve update rate 2 Hz
Max recommended pressure 7 bar
Internal diameter 0.5 mm
Internal volume(1) 3.5 µL
Carryover volume(2) 1.7 µL
Dead volume (3) None
Wetted materials PCTFE, PTFE
Number or ports 13
Number of positions 12
Operating temperature 5-40°C
Operating Humidity 20-70% noncondensing
  1. Volume inside the system from entrance to exit
  2. Volume of liquid that will be mixed with the next liquid. It is not stuck, but will be swept next time a liquid passes.
  3. Volume that is stuck in the system (dead end), which is not clearly swept and relies on diffusion to clear out

product-img

Need help or technical information?
Talk to an expert

Software

A free software for all instruments

Powerful, modular and versatile set-up control solution

The ESI software can control up to 16 Instruments through the same interface. Thanks to TTL triggers you can synchronize your Elveflow system with any other instrument used in your laboratory (microscope or any electrical instrument … ). The Scheduler is a user-friendly tool to automate complex steps of your experiments and protocols.

Read more

Volume
Injection
module

Enter your targeted volume and this module will automatically adjust the flow rate at the right time to inject it.

Fluidic system optimization module

Automatic diagnostic of the fluidic path sizing and recommendations to improve your microfluidic setup.

Bubble
detection
module

Do not suffer anymore because of bubbles!

Sensor calibration module

Don’t lose precious time in calibration protocols.

Need help or advice?

For any help to determine what microfluidic instruments you need, you can contact us!
Our experts will help you build the best microfluidic setup for your application, with our state-of-the-art microfluidic line.

Contact us
Get a quote
How can we help you?
Quoteor technical request Job application Job
application
Collaboration or partnerships Collaborations
or partnerships
Customer support Customer
support
Others questions Other

    Get a quote




    We will answer within 24 hours

    By filling in your info you accept that we use your data.

    Contacting for
    a job application?
    We are happy that you are interested in Elveflow. You can apply to our open jobs or send us your open application on WelcomeToTheJungle. Over here!

      Collaborations




      We will answer within 24 hours

      By filling in your info you accept that we use your data.

        Need customer support?







        I hereby agree that Elveflow uses my personal data

        We will answer within 24 hours

          How can we help you?




          We will answer within 24 hours

          By filling in your info you accept that we use your data.