Fluid mixing represents a unit operation in industrial process engineering that involves the handling of a heterogeneous physical (gas or liquid) system to make it more homogeneous. Fluid mixing is for instance, employed to enhance heat and/or mass transfer between various components of a single system.
Fluid mixing can be described as the incorporation of one immiscible liquid into another immiscible liquid. For instance while making emulsions (water in oil or oil in water).
Fluid mixing can also imply the incorporation of gas into a liquid phase. For example, when a foam is being generated by injecting gas at high-shear rate into a solution containing soap.
Fluid mixing at micro-scale behaves very differently than at macro-scale. Indeed, at this scale, diffusion is dominant and normal advection does not occur unless it is forced by a hydraulic pressure gradient.
Diffusion is a slow mechanism. Therefore, many researchers looked for ways to enhance fluid mixing, and created microfluidic micromixers.
To evaluate the mixing efficiency, and the dominant mechanisms at stake during the mixing process, an adimensional number named the Peclet number (Pe) is commonly employed – It describes the ratio of advection to diffusion. For Pe > 1: advection dominates & For Pe < 1, diffusion dominates.
Pe = (flow velocity × mixing path) / diffusion coefficient
Active development and improvement of microfluidic devices have led to make tremendous progress in various engineering fields of application from biomedical diagnostics studies, development of miniaturized microfluidic and nanofluidic biosensors, in DNA analysis, chemical synthesis to genomics studies.
Indeed, the channel dimensions in microfluidic systems are measured in micrometers. This allows the operator to decrease drastically sample/reagent consumption which is an important advantage for many fields of application.
Sample flow at microscale is laminar which corresponds to a small Reynolds number. Thus, in such a laminar flow, traditional turbulent mixing between two liquids cannot occur. Nevertheless, controllable and fast mixing is critical for many field of application which led to many subsequent practical development of microfluidic and lab-on-chip devices often used for assays involving many reagents and samples.
Numerous microfluidic techniques were found by researchers to enhance mixing from the use of Y junction and T junction devices, three-way intersections and designs where the interfacial area between the two fluids is enhanced to twisting channels (multilayered, looped, wavy) to force two fluids to mix.
Example of microfluidic serpentine mixer in a microfluidic setup
Various microfluidic fluid mixers were developed over the past two decades. Two categories of microfluidic fluid mixers: passive and active fluid mixers.
Microfluidic passive mixers with elongated channels allow to enforce diffusion mixing with for instance so-called “herringbone” mixing structure.
Microfluidic active mixers with integrated stir bars enable to generate mixtures with a wider range of mixing ratios (up to 1:10 mixing ratio) such as serpentine mixers.
Passive microfluidic mixing implies that no active elements are involved in the mixing process. In this case, channels geometry is designed to increase the contact area or/and the contact time between the fluids involved in the mixing process.
The first passive method to increase mixing between liquids involves enhancing diffusive effects between samples. To do so, samples can be flowed through various holes incorporated in a microfluidic chip, or samples can be split between multiple smaller channels.
The second passive approach is to increase the contact area and the duration of contact between the two fluids to be mixed.
Depending on the type of passive micromixer, mixing time can vary from tens to hundreds of milliseconds (see Table I).
Table I: Comparative table of performances for different passive micromixers (2).
Microfluidic passive micromixers also comprise of the following:
Please refer to “Microfluidic mixers – a short review” for more insights.
In an active approach, mixing efficiency is increased by external forces applied to the samples.
To perform active microfluidic mixing, specific mechanical transducers should be incorporated into the microfluidic chip.
To implement “active” fluid mixing, various techniques can be used from acoustic waves, pressure perturbations, magnetic field, and thermal methods. For example, generation of acoustic waves in the mixing area will increase interfusion between samples. However the involved external forces could influence the studied samples. Another drawback for active approach can be found for ultrasonic waves: they can provoke non negligible sample heating that can cause undesirable reactions between the samples specifically for biological application where samples are very sensitive to external perturbations and temperature variations. Mixing time and effectiveness depend also on the type of active mixer (see Table II).
Table II: Comparative table of performances of different active micromixers (2).
However, mixing efficiency can be increased by the combination of active and passive methods resulting in more complex channel geometries. Microfluidic active micromixers also comprise the following:
Please refer to “Microfluidic mixers – a short review” for more insights
Email* I hereby agree than Elveflow uses my personal data
Do you want tips on how to best set up your microfluidic experiment? Do you need inspiration or a different angle to take on your specific problem? Well, we probably have an application note just for you, feel free to check them out!
This short note will introduce you to the key takeways about microfluidic T junction among other microfluidic junctions.
In the past two years, several new microfluidic syringe pump systems have changed the use of syringe pumps in microfluidic experiments.
This review presents a few examples of applications where magnetic flux sources, magnetic particles and microfluidics are combined in order to perform particle sorting and handling.
In microfluidic laminar flows, traditional turbulent mixing between two liquids cannot occur. However, controllable and fast mixing is critical for microfluidic and lab-on-chip devices. So different mixing techniques were developed and are here presented.
There are three main classes of systems to control liquid motion in microfluidic and nanofluidic devices.
One of the great challenges for researchers using microfluidics is miniaturizing analysis processes in very small microchip.
Microfluidic flow controllers are designed to control flows in microfluidic chips.
Despite their sturdiness & simplicity, syringe pumps are often problematic in microfluidics.
The performance of your flow control instruments depends on your experimental conditions.
Liquid flow sensors are a compulsory element of microfluidic systems requiring a control of the sample volume dispensed and/or, obviously, the sample flow rate.
What are the strengths and weaknesses of each type of microfluidic flow control system? Pressure controller, syringe pump...?
Fast medium switch in microfluidic channels is generally a required technique to perform a wide range of biomedical and chemical microfluidic assays, such as the analysis of living cells in vitro, particle washing, etc.
Outside of conventional syringe pumps which generate flow oscillation at low flow rate and long settling time, we can now find syringe pumps like the NE-1002X which is dedicated to microfluidic experiments.
Common syringe pumps have two major drawbacks when it comes to research in MICROFLUIDICS: RESPONSIVENESS and flow OSCILLATION/PULSATILE FLOW. Recently, some syringe pump manufacturers have developed...
High accuracy microfluidic pumps are important for many applications from dynamic cell culture to droplet or nanoparticle generation.
Get a quote
Name*
Email*
Message
Newsletter subscription
We will answer within 24 hours
By filling in your info you accept that we use your data.
Collaborations
Need customer support?
Serial Number of your product
Support Type AdviceHardware SupportSoftware Support
Subject*
I hereby agree that Elveflow uses my personal data Newsletter subscription
How can we help you?
Message I hereby agree that Elveflow uses my personal data Newsletter subscription