Home / PDMS membrane station
Microfabrication stations

PDMS membrane Station

Make your own PDMS membranes
High precision & wide thickness range

Low vibration spin coater to control speed, acceleration, and thickness

No PDMS ageing

10 minutes protocol of repeatable and reproducible experiments

Easy to Use

We provide tutorials to produce high-standard membranes

Turnkey Station

All required equipment and accessories for complete autonomous PDMS membrane manufacturing

Talk to an expert

Features & benefits

Benefits

  • Easily and quickly create your own PDMS membranes.
  • Precise control over your PDMS membrane thickness.
  • Robust processes to enable easy reproducibility.
  • Fabricate your membrane without initial knowledge of microfabrication.
  • Get the best equipment to ensure your facility for  long lifetime.

Included

Equipment:

  • Highly versatile Spin Coater
  • Air compressor
  • Vacuum pump
  • Hot plate for photoresist and PDMS baking

 

Accessories:

All lab accessories (glass slides, Petri dishes, disposable cups, stirring rods, scalpels, etc.) are included. We give you all the products’ references and providers’ information to refill your stock.

Microfluidic accesory softlithobox
Chemicals:

All chemicals (PDMS, TMCS, AZ4562, Isopropanol, Acetone, etc.) are included. We give you all the products’ references and providers’ information to refill your stock.

Chemicals microfluidic SU8 developer isopropanol aceton TMCS

Support

  • Standard support pack: We take care of the after sale of all your instruments, we provide you microfabrication process-sheet and tutorials, and we provide you 1-year phone assistance to answer any microfabrication questions you could have.
  • Extended support pack: In addition to the standard pack our R&D team installs the Softlithobox directly in your lab, we adapt on site all our microfabrication processes to your needs, and we train your team until they become ready to fabricate all your microfluidic chips.

Spin coater

SPIN caoter BLACK

We offer you all the equipment, accessories, and chemicals needed to make highly reproducible PDMS membranes. Prepare your PDMS, choose the thickness, and quickly create your PDMS membranes for your experiment in less than one hour!

Our system ensures you:

  • highly reproducible PDMS membranes
  • Easy manufacturing of PDMS membranes
  • High-precision PDMS membrane thickness
  • Wide range of PDMS membrane thickness

Vacuum pump / Air compressor

Compresseur-datasheet

The Spin coater needs a 4bar pressure and vacuum access to work correctly. The vacuum is used to maintain the wafer on the chuck, and the pressure protects the Spin coater from the liquid, photoresist, or PDMS from getting inside the rotor.

We also provide an efficient, powerful, and noiseless vacuum pump and air compressor in case your laboratories do not have pressurized air or vacuum lines, or if you wish to install your station anywhere in your facilities.

Hot plate

hotplates-tuto microfluidic chip soft lithography

Our hot plate is ideal for the final steps of hardening the PDMS or – depending on the process – baking some photoresist.

We offer a simple and efficient hot plate with the best quality and price conditions.

An adaptive offer!

Since each laboratory is different, since each research is unique, we do adapt the offer to be as close as possible of the real need. We discuss together what will be the best efficient facility and thus add or remove equipment, accessories, chemicals.

Do not hesitate to ask one of our technico-commercials to make an assessment of your facility and to advise you on your project.

Options

We have created basic offer with every thing needed to have a complete working set, but some option can be add according to each situation. We have selected some option commonly use during softlithography process but do not hesitate to ask our engineer if you have special expectations.

Developer Agitator

Developer-agitator

Optical profiler

Optical Profiler

Little fume hood – Extractor3.5

Little-Fume-Hood

Need help or technical information?
Talk to an expert

Need help or advice?

For any help to determine what microfluidic instruments you need, you can contact us!
Our experts will help you build the best microfluidic setup for your application, with our state-of-the-art microfluidic line.

Contact us
Contact
How can we help you?
Quoteor technical request Job application Job
application
Collaboration or partnerships Collaborations
or partnerships
Customer support Customer
support
Others questions Other

    Get a quote




    We will answer within 24 hours

    By filling in your info you accept that we use your data.

    Contacting for
    a job application?
    We are happy that you are interested in Elveflow. You can apply to our open jobs or send us your open application on WelcomeToTheJungle. Over here!

      Collaborations




      We will answer within 24 hours

      By filling in your info you accept that we use your data.

        Need customer support?







        I hereby agree that Elveflow uses my personal data

        We will answer within 24 hours

          How can we help you?




          We will answer within 24 hours

          By filling in your info you accept that we use your data.