Archived content. See more recent content: Application notes & reviews
Obsolete!
See the new product page here
A high accuracy vacuum source which generates negative pressure for microfluidic flow control without installation/connection of any instrument such as a vacuum line or pump. It allows to generate and control negative pressure down to -600mBar (-8.7 psi) with a precision of 1mBar (0.0145 psi).
.
Autonomous: Integrates both the vacuum controller and the vacuum source, no need for compressor/gas line.
Transportable: Weight 1.2kg, small size : 15x15x20 cm.
Quick setup: 5 min for the first installation, setup a new experiment in 2 minutes.
Accurate: 1 mbar tuning precision (0.0145 psi).
USB control option: Control vacuum in your microchip with your computer and Elveflow® proprietary software.
Both vacuum and flow rate control and monitoring: No more need to choose between vacuum control or flow rate control.
Elveflow® autonomous vacuum source integrates both the vacuum controller and the vacuum generator in the same equipment. It allows a microfluidic flow control and to setup a microfluidic experiment by simply plugging an electric plug and the fluidic connection between the microfluidic device and the Elveflow® vacuum source.
Transient pressure drop when opening the valve
When opening the outlet valve of the vacuum source, the suction pressure measured by the sensor briefly (~1 sec) decreases before stabilizing at its initial value. This comes from the fact that before opening, the valve the sensor measures the suction pressure inside the generator and at the opening of the valve it measures a mean between suction pressure inside the generator and inside the microfluidic device connected to the outlet. The measured suction pressure quickly comes back to its initial value when the pressure on the microfluidic device becomes equal to the pressure in the vacuum source. To reduce this time-lapse, one can reduce the dead volume between the vacuum source and the microfluidic device.
Small permanent pressure shift when opening the valve of the vacuum source
When opening the valve for the first time after setting the suction pressure with the tuning button, the displayed pressure permanently shifts by one or two mbar. This comes from the fact that the membrane of the internal vacuum regulator changes position with the first opening of the outlet. This phenomenon does not occur for further valve switches.
Vacuum source warm up
During the first 15 minutes of utilization the pressure of the vacuum source might change due to the components warming up. To get optimal performance we recommend turning on the vacuum source at least 15 minutes before the beginning of your microfluidic experiment.
Friction of the vacuum tuning button
The pressure tuning button is directly linked to the spring of the internal regulator. The spring of the vacuum regulator is compressed when decreasing the pressure. The compression of the spring leads to a sensation of friction when turning the knob at the top of the pressure range.
Email* I hereby agree than Elveflow uses my personal data
Get a quote
Name*
Email*
Message
Newsletter subscription
We will answer within 24 hours
By filling in your info you accept that we use your data.
Collaborations
Need customer support?
Serial Number of your product
Support Type AdviceHardware SupportSoftware Support
Subject*
I hereby agree that Elveflow uses my personal data Newsletter subscription
How can we help you?
Message I hereby agree that Elveflow uses my personal data Newsletter subscription