Microfluidic flow controllers are designed to control flows onto microfluidic chips. For most researchers in the microfluidic community, responsiveness is an essential parameter for realizing on-chip tasks and optimizing the performance of a microfluidic setup.
The following graphics compare experiments that use the OB1 flow controller, with experiments using other microfluidic flow controllers available on the market. With OB1 piezo technologies, you consistently get fast microfluidic flow control with any sample volume.
The graphics below show the reactivity of competing flow controllers for the best configuration of sample volume that we found (1mL) versus the reactivity of OB1 for a common microfluidic sample volume (12mL !)
According to the IBM Dictionary of Computing (which cites as its source the International Organization for Standardization’s Information Technology Vocabulary) and the US Federal Standard Glossary: Responsiveness is the ability of an entity to provide service within the required time. Responsiveness thus determines the global ability of a system to reach a setting point. In a microfluidic setup, responsiveness depends on all the elements of the setup. For example, in the case of pressure controllers system, responsiveness depends on the volume of air that gets pressurized.
To determine the performability of a microfluidic flow controller, the following time factors must be defined :
The latency is the time interval between the initiation of a sent operation by a source task and the completion of the matching received operation by the target task. More generally, latency is the time delay between the moment an operation is initiated, and the moment it begins to take effect. In microfluidics, latency is the time needed by the microfluidic flow controller to simply react to the set order.
The processing time is the amount of time a system takes to process a given request. It does not include the time it takes the order to get from the user to the system. In microfluidics, processing time is the time needed between the reaction of the microfluidic flow controller and the first move in the setup.
The response time is the time a system or functional unit takes to react to a given input.
It corresponds to the elapsed time between the end of an inquiry on a system and the beginning of a response by the microfluidic flow controller.
In microfluidics, response time is the length of time between an indication of the start of flow and the display of the first change in flow at a user’s workstation (camera, sensor, monitoring station…).
In these terms:
Latency + Processing Time = Response Time
The rise time is the time a system takes to change from a specified low value to a specified high value. The rise time is defined as the time required for the response to go from x% to y% of the setting value. The 10% to 90% rise time is the one most commonly used.
In microfluidics, the rise time is the time needed to reach, commonly, from 10% to 90% of the setting flow.
The settling time is the time elapsed from the application of some flow to the time at which the flow has entered and remained within a specified error margin of the final value. The settling time includes the response time, plus the rise time and finally, the time needed to be within the specified error margin.
In microfluidics, the settling time is commonly defined as the time needed for the response of flow to reach and stay within a certain percentage range, usually 2% or 5% of the desired final value of the flow.
Email* I hereby agree than Elveflow uses my personal data
Do you want tips on how to best set up your microfluidic experiment? Do you need inspiration or a different angle to take on your specific problem? Well, we probably have an application note just for you, feel free to check them out!
Revolutionizing Microfluidics with Acoustic Particle Manipulation
This short note will introduce you to the key takeways about microfluidic T junction among other microfluidic junctions.
Fluid mixing at microscale is of importance for many fields of application. This short review summarises the key takeaway aspects of fluid mixing at microscale.
In the past two years, several new microfluidic syringe pump systems have changed the use of syringe pumps in microfluidic experiments.
This review presents a few examples of applications where magnetic flux sources, magnetic particles and microfluidics are combined in order to perform particle sorting and handling.
In microfluidic laminar flows, traditional turbulent mixing between two liquids cannot occur. However, controllable and fast mixing is critical for microfluidic and lab-on-chip devices. So different mixing techniques were developed and are here presented.
There are three main classes of systems to control liquid motion in microfluidic and nanofluidic devices.
One of the great challenges for researchers using microfluidics is miniaturizing analysis processes in very small microchip.
Despite their sturdiness & simplicity, syringe pumps are often problematic in microfluidics.
The performance of your flow control instruments depends on your experimental conditions.
Liquid flow sensors are a compulsory element of microfluidic systems requiring a control of the sample volume dispensed and/or, obviously, the sample flow rate.
What are the strengths and weaknesses of each type of microfluidic flow control system? Pressure controller, syringe pump...?
Fast medium switch in microfluidic channels is generally a required technique to perform a wide range of biomedical and chemical microfluidic assays, such as the analysis of living cells in vitro, particle washing, etc.
Outside of conventional syringe pumps which generate flow oscillation at low flow rate and long settling time, we can now find syringe pumps like the NE-1002X which is dedicated to microfluidic experiments.
Common syringe pumps have two major drawbacks when it comes to research in MICROFLUIDICS: RESPONSIVENESS and flow OSCILLATION/PULSATILE FLOW. Recently, some syringe pump manufacturers have developed...
Get a quote
Name*
Email*
Message
Newsletter subscription
We will answer within 24 hours
By filling in your info you accept that we use your data.
Collaborations
Need customer support?
Serial Number of your product
Support Type AdviceHardware SupportSoftware Support
Subject*
I hereby agree that Elveflow uses my personal data Newsletter subscription
How can we help you?
Message I hereby agree that Elveflow uses my personal data Newsletter subscription