Complete setup for precise and controlled MERFISH/seqFISH experiments
Can control the flow of more than 23 solutions simultaneously
Synchronize perfusion and imaging through TTL triggers and SDK
Stable and automated system for better reproducibility
Faster experiments that use less volume of expensive solutions
Schematics outlining multiplexed RNA and protein detection methods by Mayr U. et al.
This all-included, user-friendly, customizable, and automatable instruments pack is ideal for MERFISH/seqFISH/seqFISH+ experiments but can be easily adapted to other applications.
The pack is compatible with different instruments, and the entire setup is controlled via a single software.
This pack includes our premium Elveflow product line and our best-seller, the OB1 flow controller. Thanks to the high performance of this equipment, you will be able to:
*The sequence scheduler automatizes the platform to flow a large number of different solutions easily. Our experts can help you integrate your experiment using TTL triggers or direct software integration via SDK.
This pack is designed to be:
It allows you to perform multiplexed fluorescence in situ hybridization at a microfluidic scale, significantly decreasing the cost of each experiment by reducing the volume of the reagents required.
Elveflow microfluidic platforms are perfectly suited for long-term experiments with excellent stability and no risk of potentially harmful pressure spikes.
All the pack items are adjustable to your laboratory infrastructure and experimental requirements.
Fig 1: This is an illustrative setup example. The solutions’ number and volume can be adjusted according to the experimental requirements and protocol.
seqFISH is a highly sensitive technique that accurately detects low-copy number genes often not detected with single-cell RNAseq or immunostaining. Additionally, reverse transcription or PCR amplification often biases quantification in RT-PCR and RNA sequencing. Because seqFISH can be applied to any tissue type without preselecting genes, it enables the unbiased discovery of novel genes relevant to certain biological phenomena.
seqFISH generates accurate in situ quantification of mRNA levels [1]
SeqFISH and MERFISH use probe detection for single-cell spatial transcriptomics [1][2][3].
At first, in situ hybridization is done with one set of fluorescent FISH probes and a labeling dye. DNase is then used to remove the fluorophores, and the mRNA is hybridized with the identical FISH probes again but with a different labeling dye. The several rounds of hybridization and other dyes allow the barcoding of several genes in a single cell [4].
SeqFISH+ is the improved seqFISH technique ideal for spatial and biological processes studies of cells. It combines seqFISH with a confocal microscope generating super-resolution imaging and multiplexing of 10,000 genes in a single cell [5].
Multiplexed Error Robust Fluorescence In Situ Hybridization (MERFISH) is the improved single-molecule Fluorescence In Situ Hybridization (smFISH). The method massively parallelizes and simultaneously spatially identifies hundreds of thousands of RNA species. In addition, this method detects errors that can then be corrected in an error-robust way thanks to the use of some unassigned binary barcode. This is the main difference compared to seqFISH, which is coded in a color sequence [6].
Lab-on-chip technologies and microfluidic platforms improve seqFISH and MERFISH methods by reducing the cost and the experiment time, providing automation to the process, and improving reproducibility [7].
*Chips are available in several materials, heights, widths, lengths, and shapes, with different numbers of inlets/outlets, and are compatible with different FISH methods. We can advise you on different chips to fit this pack.
Build your pack in three quick and easy steps:
“I found the systems quite robust, easy to connect and use”Dr. Martino Chiara, ETH Zurich, SwitzerlandOB1 pressure-driven flow controller user
“Thanks to Elveflow products, we can focus on our results rather than the tedious instrumentation. We especially appreciate the Elveflow system when it comes to droplet based systems which requires the control of multiple flows simultaneously. ”Dr. Caglar Elbuken, Bilkent University, TurkeyOB1 pressure-driven flow controller user
“We are satisfied with the ELVEFLOW instrument, the regulation accuracy is well fitted with our applications. The advantage of this instrument is the capability it offers to easily move the experiments anywhere you want. This feature is very convenient, especially when we encapsulate cells into droplets in cell culture platforms.”Pr. Annie Viallat, Adhesion & Inflammation Lab CNRS UMR 6212 Inserm UMR 600, FranceOB1 pressure-driven flow controller user
“We are very satisfied of the ELVEFLOW pressure pumps! The ELVEFLOW pressure pumps enable us to perform portable experiments with accurate pressure control.”Dr. Wiebcke Drenckhan, Liquids Interfaces Group of the Physic of Solids Lab - CNRS UMR 8502 Orsay University, FranceOB1 pressure-driven flow controller user
“The advantages of this instrument are its ease of use and the accuracy of the regulated pressure. This feature is very convenient, especially when we perform foams and microfluidic.”Dr. Pascal Panizza, Soft Matter Department of IPR – CNRS UR1 UMR6251, FranceOB1 pressure-driven flow controller user
“I was suprised how quickly I was able to get things to work once I got going.”Jamie Stover, Research Assistant, M. Zernicka-Goetz Lab at California Institute of Technology (Caltech)OB1 pressure-driven flow controller user
Using microfluidics is the most efficient method to perform MERFISH (Multiplexed Error-Robust Fluorescence In Situ Hybridization) or seqFISH (sequential Fluorescence In Situ Hybridization) and observe multiple genes and their spatial configuration because:
This pack can be combined with other microfluidic steps before this fluorescent in situ hybridization setup. For example, for single-cell isolation, you can use microfluidic single cell encapsulation [1].
Microfluidics can also be used for the method called MA-FISH, which uses oscillatory flows of diluted probe solutions or to perform barcoding (DBiT-seq).
Elveflow has been the microfluidic flow control expert company for more than 10 years and can provide its state-of-the-art expertise in biology and engineering, thus, being the perfect partner for you to transition to microfluidics.
Schematics outlining multiplexed RNA and protein detection methods. [1]
[1] Mayr U., Serra D., Liberali P. Exploring single cells in space and time during tissue development, homeostasis and regeneration. Development, 2019, 146(12),
For any help to determine what microfluidic instruments you need, you can contact us! Our experts will help you build the best microfluidic setup for your application, with our state-of-the-art microfluidic line.
Get a quote
Name*
Email*
Message
Newsletter subscription
We will answer within 24 hours
By filling in your info you accept that we use your data.
Collaborations
Need customer support?
Serial Number of your product
Support Type AdviceHardware SupportSoftware Support
Subject*
I hereby agree that Elveflow uses my personal data Newsletter subscription
How can we help you?
Message I hereby agree that Elveflow uses my personal data Newsletter subscription