Droplet based microfluidics
This user guide will show you how to run microfluidic colocalization studies of single molecule spectroscopy. We will start with the preparation of the flow cell and we will then show you how to apply pressure driven flow control to liquids for DNA detection studies.
Schematic depiction of DNA and protein colocalization. Single DNA molecules are attached to the glass surface using streptavidin as intermediate bonding agent. In this article we will describe how to perform microfluidic colocalization using an Elveflow set-up.
The bottom part of the chip is made of borosilicate glass, 0.13-0.17 mm. The top glass (cover glass) is a conventional microscope glass slide. The biggest channel length is 40 mm, the smallest 20 mm. Channel depth may differ, here 20-, 30- and 50-micron channels were etched. The chip was produced by glass etching during the study. Channel width was 150 microns. On the top of the microscope glass slide we drilled inlet and outlet holes. Connectors: custom, made as part of the project. Tubing: external diameter 1 mm.
Tips from the expert: Before starting the experiment, proteins and DNA should be labelled and purified using gel filtration. The extended protocol can be requested (classical protein purification).
Tips from the expert: Use consecutive MUX inlets for liquid reservoirs and the dead-end. The MUX will switch liquids following the shortest travel distance. Air will enter the system if the MUX passes over an open inlet.
Tips from the expert: Chip priming: To begin with, run liquids into tubes until the liquid starts to drip for each inlet of the MUX distribution. Only then, connect them to the chip.
a. 10 µL of PBSb. 5 µL of bio-BSA 0.1 mg/mL PBSc. 5 µL of PBSd. 5 µL of Pluoronics 0.5%e. 5 µL of Neutravidin 0.2 mg/mLf. 5 µL of Casein 0.02%g. 5 µL of 20kb DNA bio (1 µL-0.5 ng) in PCB (19 µL)
Tips from the expert: PBS is Phosphate Buffered Saline and PCB is PBS with BSA (0.4 mg/mL) and casein (0.02%).
a. 5 µL PCBb. 5 µL Neutravidin 0.2 mg/mLc. 5 µL of Pluronics 0.5%
Congratulations – you achieved the binding and monitoring of single molecules on chip! We hope this tutorial is a useful guide in your microfluidic experiments. If you need further details or additional information, do not hesitate to contact our experts!
This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No 722433 (DNARepairMan).
How can we help you?
Name*
Email*
Message
Newsletter subscription
We will answer within 24 hours
By filling in your info you accept that we use your data.
Do you want tips on how to best set up your microfluidic experiment? Do you need inspiration or a different angle to take on your specific problem? Well, we probably have an application note just for you, feel free to check them out!
Microfluidics is the science of handling small amounts of liquids, inside micrometer scale channels. Discover how to handle fluids for your microfluidic experiments.
This application note demonstrates a smart use ouf Elveflow's Pressure sensor and sensor reader for Direct-Ink-Writing flow control.
Learn how to set up your development environment for Elveflow products with this comprehensive tutorial.
This application note explores the basic principle of pneumatic pumps and a flow controller based on the basic principle of pneumatic pumps, known as pressure driven flow control. It also demonstrates the applications of pressure driven flow control in a range of industrial & research fields.
Flow regulation is a compulsory operation in most of the microfluidics operations. In some applications such as 2D or 3D cell culture, flow regulation is essential since accurate micro-environmental parameters control is required. Elveflow do it’s best to make this operation as easy as possible to help you to focus on what really matter in your setup.
Study the impact of molecular transport on cell cultures with a cross flow membrane chip and microfluidic instruments.
Precise liquid injection system for manipulation of small volumes of fluids using the MUX distribution and the MUX recirculation valve.
This application note explains how to set up a robust and reproducible microfluidic platform for liposomes assembly with improved encapsulation efficiency and reduced polydispersity in size.
Single-wall carbon nanotubes (SWCNTs) are considered as quasi 1-dimensional (1D) carbon nanostructures, which are known for their outstanding anisotropic electronic, mechanical, thermal and optical properties.
This application note describes how to combine and synchronise liquid perfusion and imaging using an Olympus spinning disc confocal microscope together with an Elveflow pressure-driven flow controlled microfluidic system.
Mixing is a crucial step for several microfluidic applications like chemical synthesis, clinical diagnostics, sequencing and synthesis of nucleic acids
This application note describes how microfluidic can be employed as a nanoparticle generator based on the example of PLGA bead generation.
Learn how to perform PLGA nanoparticle preparation with Elveflow instruments and a microfluidic chip
The application note describes how to convert various units of shear stress and/or pressure from one to another: shear stress conversion from Pascal, atmosphere, and N/m²...!