Elveflow developped a free online microfluidic calculator.
This application note describes how to calculate key microfluidic parameters from the flow rate, the shear stress and the microfluidic resistance of your channel.
This tool has been designed to help researchers and especially non-specialists of the microfluidics field. It helps you assess key parameters to configure your microfluidic experiment.
It should be noted that every microfluidic chip and setup are different. Here, we use a generic microfluidic system to give you a basic understanding of the parameters to select the right components for your setup.
This microfluidic calculator can be applied to many situations in the lab, at different stages of setup preparation.
Here are some of the many applications made easier by this calculator:
The first component of any microfluidic system is the pump or the pressure source, which is required to drive the fluid from the reservoir through the tubing into the microfluidic chip. As an analogy, we can think of the flow of the fluid to be the flow of electricity. In order to drive electricity through a circuit or device, you need a power source, like a battery. In a similar manner, we required either a pump or a pressure source to drive the fluid to the reservoir through the microfluidic chip.
For more information about the working principle of the pressure-driven flow controller developed by Elveflow, please watch this application note.
The pump or the pressure source is a crucial component of the system, together with the design of the chip. The pressure unit of your source will determine the highest and the lowest flow rate that are achievable in your microfluidic system.
Here is an example of the importance of the choice of the pump or pressure source for droplet-based microfluidics.
The second critical part of your system is the medium and its properties like density and viscosity that determine the flow regime of the overall system.
For example, a less viscous fluid like water requires less force to be pumped into your chip compared to oil or glycerol with high viscosity. Together, density and viscosity play an important role in the flow physics in your experiment.
Apart from this, the tubing that is used to connect the fluid reservoir and the microfluidic chip also, in some cases, impacts the flow parameters of your system.
Indeed, if you consider fluid to be electricity, all the elements it flows through, such as tubing and the microfluidic channels can be considered like wires. Like electrical wires, channels and tubing have a certain amount of resistance to flow, commonly referred to as hydraulic resistance.
It is easier to suck up liquid through a thick straw than through a very thin one. The longer the straw, the more force you have to use.
The dimensions of the tubings, like inner diameters and length, determine the hydraulic resistance. For more insight into the basics of microfluidic tubings and sleeves, please check this review.
Last and important part of the system is the microfluidic chip itself.
Like the tubing, the dimension properties of the channels determine the hydraulic resistance of the system.
For biological experiments, the channel dimensions also play an important role to determine key experimental conditions, like the quantity of shear stress acting on cells attached to the wall of the microfluidic channel.
For the purposes of this tool, we have considered a very simple microfluidic channel. A straight channel with an inlet and outlet, like IBIDI chip for cell culture.
How can we help you?
Name*
Email*
Message
Newsletter subscription
We will answer within 24 hours
By filling in your info you accept that we use your data.
Do you want tips on how to best set up your microfluidic experiment? Do you need inspiration or a different angle to take on your specific problem? Well, we probably have an application note just for you, feel free to check them out!
Microfluidics is the science of handling small amounts of liquids, inside micrometer scale channels. Discover how to handle fluids for your microfluidic experiments.
This application note demonstrates a smart use ouf Elveflow's Pressure sensor and sensor reader for Direct-Ink-Writing flow control.
Learn how to set up your development environment for Elveflow products with this comprehensive tutorial.
This user guide will show you how to run microfluidic colocalization studies of single molecule spectroscopy.
This application note explores the basic principle of pneumatic pumps and a flow controller based on the basic principle of pneumatic pumps, known as pressure driven flow control. It also demonstrates the applications of pressure driven flow control in a range of industrial & research fields.
Flow regulation is a compulsory operation in most of the microfluidics operations. In some applications such as 2D or 3D cell culture, flow regulation is essential since accurate micro-environmental parameters control is required. Elveflow do it’s best to make this operation as easy as possible to help you to focus on what really matter in your setup.
Study the impact of molecular transport on cell cultures with a cross flow membrane chip and microfluidic instruments.
Precise liquid injection system for manipulation of small volumes of fluids using the MUX distribution and the MUX recirculation valve.
This application note explains how to set up a robust and reproducible microfluidic platform for liposomes assembly with improved encapsulation efficiency and reduced polydispersity in size.
Single-wall carbon nanotubes (SWCNTs) are considered as quasi 1-dimensional (1D) carbon nanostructures, which are known for their outstanding anisotropic electronic, mechanical, thermal and optical properties.
This application note describes how to combine and synchronise liquid perfusion and imaging using an Olympus spinning disc confocal microscope together with an Elveflow pressure-driven flow controlled microfluidic system.
Mixing is a crucial step for several microfluidic applications like chemical synthesis, clinical diagnostics, sequencing and synthesis of nucleic acids
This application note describes how microfluidic can be employed as a nanoparticle generator based on the example of PLGA bead generation.
Learn how to perform PLGA nanoparticle preparation with Elveflow instruments and a microfluidic chip
Get a quote
Collaborations
Need customer support?
Serial Number of your product
Support Type AdviceHardware SupportSoftware Support
Subject*
I hereby agree that Elveflow uses my personal data Newsletter subscription
Message I hereby agree that Elveflow uses my personal data Newsletter subscription