Upgrade your OB1 pressure controller
Expand your OB1 capabilities with our upgrades.
Get the best of Elveflow innovation
Upgrade the versioning of your OB1.
Adjust your equipment to fit your needs
Add and or replace channels to fit to your experiments.
Get a complete check-up to start as new
Calibration and accuracy check as a new warranty for your old instrument.
HIGHLIGHTS
Newest versionning:
We continuously improve our OB1 pressure controller hardware, firmware, communication strategy… If you are in possession of an old OB1 you can contact us to see how it can be upgraded.
Adding channel(s):
Our main product, the OB1 pressure controller can have from 1 to 4 channels. If you buy a system without the full slots filled you can send back the system and add one or several channels to top up 4.
Replacing channel(s):
Elveflow offers a wide range of pressure ranges, 3 x positive (0_200mbar, 0_2000mbar and 0_8000mbar) and 2 duals (-900_1000mbar and -900_6000mbar). It may happen that for any reason the range you have is no longer adapted to your needs. No worry we can replace a range by another.
SPECIFICATIONS
The table below shows the main differences between the OB1 versions:
| Model | ![]() MK2 |
![]() MK3 |
![]() MK3+ |
![]() MK4 |
|---|---|---|---|---|
| Screen | No screen | Showing pressure and sensors value controlled by the ESI | Showing pressure and sensors value controlled by the ESI | Autonomous screen with automatic digital sensor detection |
| Digital Sensors | No | No | Reading once at a time | Reading in parallel |
| Communication | USB via NI technology (Windows only) | USB via NI technology (Windows only) | USB via NI technology (Windows only) | USB via serial communication (OS agnostic) |
| Calibration in test bench | No | No | Yes | Yes |
HOW TO CHOOSE YOUR DEVICE
Depending on the sensors you might already have, we advise you to check the compatibility of these sensors with the different OB1 versions when requesting for an update of your instrument. Indeed some old sensors are not compatible with the newest OB1 versions.
- If you have an OB1 MK2 or MK3 and would like to upgrade to a MK3+, please check the table below:

- If you have an OB1 MK2 / MK3 or OB1 MK3+ and would like to update to a MK4, please check the table below:

FAQ
Can I receive a replacement during the upgrade of my OB1 system?
To minimize the downtime during the upgrade of your OB1 system, we offer the option to rent an equivalent system for up to one month. This allows you to continue your experiments without interruption. For more information, contact our experts.
What is the typical duration for an OB1 upgrade?
The upgrade process for your OB1 typically takes less than two weeks, excluding shipping time. Please note that during the upgrade, we conduct a comprehensive evaluation of your equipment. If additional repairs are necessary, the process may extend slightly longer.
Is it possible to add any pressure range to an OB1?
Yes, you can add any pressure range to your OB1 if there is an available slot, regardless of the existing channel(s) configuration.
Upgrade your OB1 pressure controller
Get the best of Elveflow innovation
Upgrade the versioning of your OB1.
Adjust your equipment to fit your needs
Add and or replace channels to fit to your experiments.
Get a complete check-up to start as new
Calibration and accuracy check as a new warranty for your old instrument.




