There are two methods to prepare ferrofluids:
- One-step method: nanoparticles are fabricated in base fluids directly
- Two-step method: nanoparticles are first fabricated and then separated and redispersed in base fluid.

Figure 1: Ferrofluid on a reflective glass plate under the influence of a strong magnetic field (Wikipedia).
Ferrofluids exhibit superparamagnetic properties. Superparamagnetism means that the particles are magnetized when a magnetic field is present, but when the magnetic field is removed they behave like nonmagnetic materials as they have no magnetic memory.
Thermomagnetic convection in ferrofluids
The magnetic particles in a ferrofluid are small enough to contain a single magnetic domain, and the net magnetization is hence temperature dependent. Below a critical temperature, referred to as the Curie temperature (TC), the magnetic moments of the ferrofluid are aligned in a one direction resulting in a net magnetization. As the temperature exceeds the Curie temperature the magnetic moments become randomly oriented and the ferrofluid loses its net magnetization. An applied thermal gradient thus results in a non-uniform magnetization and the ferrofluid will experience a body force, the Kelvin body force, inducing a fluid flow along the thermal gradient. This thermomagnetic convection can drive the ferrofluid without a pump [2].
Heat transfer of ferrofluids
The thermal conductivity of magnetic nanoparticles is typically order-of-magnitude higher than the basefluid. The addition of nanoparticles therefore remarkably increases the thermal conductivity of the basefluid. This is usually quantitatively demonstrated as enhancement in thermal conductivity or enhanced convective heat transfer coefficient. Further enhancements in the heat transfer coefficient of ferrofluids have been observed when magnetic fields are applied. This is thought to be due to alignment of magnetic nanoparticles in the direction of the applied magnetic field, forming chainlike structures that provide a heat conductive pathway [3]. These results have been observed under both forced and free convective heat transfer conditions. Ferrofluids have therefore been used as heat transfer fluids, e.g. for cooling of micro devices [4].
3. Ferrofluids in microfluidic systems
An external magnetic field acting on ferrofluids in microfluidic devices can be generated by permanent magnets or electromagnets. They can be positioned outside the microfluidic device, or be integrated the into the microfluidic device. Integrated magnets have the advantage of close proximity with the fluid, thus requiring lower field strength. However, that requires more complex fabrication steps that may require clean room facilities.
Ferrofluidic pump
Hatch et al. [5] presented a ferrofluidic pump where plugs of ferrofluid were used to pump non-ferrofluids through microchannels. The ferrofluid and the non-ferrofluid must be immiscible. Their device consisted of a circular pump with two ferrofluidic plugs and two external magnets that controlled the movement of the plugs. One plug was held in place between the inlet and the outlet, acting as a closed valve. The other plug was dragged around the circle by a rotating magnet, serving as a piston, pushing and pulling the liquid in an out of the circular channel.

Figure 2. Principal sketch of a circular ferrofluidic pump. The black structures represent the ferrofluid plugs and two magnets (M) were used to move these (figure from Hatch et al. [5]).
Magnetocaloric pump
The magnetocaloric effect resulting in thermomagnetic convection, as described earlier in this review, can be used to pump fluid in a microchip. Love et al. [6] reported a magnetocaloric pump which used only a thermal field and magnetic field to drive fluid flow in a microchannel. They used a plug of ferrofluid with low Curie temperature which was attracted to a region by a magnetic field. The ferrofluid plug was then subjected to heating and as its temperature approaches the Curie temperature, the magnetic attraction of the fluid weakened and cooler fluid was then attracted to the magnetic field and displaced the heated fluid. This eventually will establish a flow and the pump was used to push non-ferrofluids through the microsystem. The principle is demonstrated in figure 3.

Figure 3. The field effect acting on the ferrofluid in a magnetocaloric pump (figure from Love et. al. [6])
Mixing
Mixing is a key concept in microfluidics and rapid mixing is essential for many biological and chemical assays. Several strategies, both passive and active, have been suggested to improve mixing efficiency. Active mixers generally provide better mixing efficiency than passive mixers, but usually also require more energy and have higher fabrication costs. Another issue with active mixers is the Joule heating that may damage biological samples. Tsai et al. [7] developed a simple low-cost y-shaped micromixer to study the mixing between a water-based ferrofluid and water. They placed a permanent magnet right below the microchannel, and varied the volumetric flowrate and channel width to obtain an improved mixing efficiency. They found that the mixing efficiency of ferrofluid and water under the influence of a permanent magnet could reach over 90%, while the mixing efficiency in the same microchannel by only diffusion was always below 15%. This type of magnetic mixer has the advantage of not consuming energy and not producing heat. Other types of magnetic micromixers have also been suggested, such as microscopic stirrer bars [8] which are rotated by conventional stirrer plates or magnetophoresis of magnetic particles [9].

Figure 4. Diffusion between DI water and water-based ferrofluid (left) without magnet and (right) with magnet (figures from Tsai et al [7])