How to generate droplets with a microfluidic droplet chip?
At a glance
This application note describes how to generate controlled-size droplets in a glass microfluidic chip by regulating pressure and/or flow rate. The procedure involves assembling the setup and controlling pressure or requesting flow values through the Elveflow smart interface. The described glass microfluidic droplet pack setup achieved controlled-size droplet generation.
- Observed result
- Controlled-size droplets using an Elveflow flow sensor and pressure control instrument
- Pressure control
- Oil and water sample pressures controlled through the Elveflow smart interface; programmable sequences
- Chip geometries
- T-junction and flow focusing
- Applications
- Emulsion production, single cell analysis, drug delivery